System
EP9224-0023
 
EP9224 | 4/4-channel power distribution for EtherCAT Box modules with current measurement/data logging
EP9224-0023
Connector assignment
Power out
Power in
Labelling areas
1 | GNDP
2 | GNDs
3 | FE
4 | +24 V DC Us
5 | +24 V DC UP
1 | +24 V DC Us
2 | +24 V DC UP
3 | GNDs
4 | GNDP
1 | Tx+
2 | Rx+
3 | Rx-
4 | Tx-
1 | Signalling contact
3 | Signalling contact
4 | Reset
Signalling
contact/reset
EtherCAT
signal input
EtherCAT
signal output
Outputs
extended temperature range

EP9224-0023 | 4/4-channel power distribution for EtherCAT Box modules with current measurement/data logging

The EP9224-0023 enables connection of four EtherCAT Box power supply branches. In each 24 V branch the current consumption for the control voltage US and the peripheral voltage UP is monitored, limited, and, if necessary, switched off.

The input voltage and current values of all outputs can be evaluated via the process data. A continuous data log of the relevant data can be retrieved when an error occurs in order to localise the cause of the error.

The power distribution is supplied via a 7/8" connector with up to 16 A (per voltage supply US/UP). Several modules can be configured in a cascade arrangement. In the event of a short-circuit in one of the four (eight) outputs, the affected output is switched off. The supply for the other branches remains active. The switch-off and control is done in such a way that the input voltage does not fall below 21 V. During startup consumers with large capacities can be added without problem.

The master can read diagnostic messages from the individual channels via the EtherCAT interface. Independent switching of individual consumer branches is also possible via the EtherCAT master.

Technical data EP9224-0023
Number of outputs 4 x M8, 4-pin (per US/UP)
Connection method M8, 4-pin
Max. output current per M8: 4 A per US and UP
Load type EtherCAT Box modules
Infeed plug 7/8", max. 16 A per US/UP
Power feed through socket 7/8", max. 16 A per US/UP
Signalling contact potential-free make contact, M8
Nominal voltage 24 V DC (-15 %/+20 %)
Distributed clocks
Bus interface 2 x M8 socket, shielded, screw type
Protocol EtherCAT
Electrical isolation 500 V
Data logging recording of relevant data in case of failure
Special features input voltages/currents, output currents via process data
Weight approx. 165 g
Operating/storage temperature -25…+60 °C/-40…+85 °C
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos. IP 65/66/67 (conforms to EN 60529)/variable
Approvals CE, UL in preparation
Accessories  
ZK1090-3xxx-xxxx Cables for EtherCAT signal in- and -output
ZK2030-xxxx-xxxx, ZK2031-xxxx-xxxx Cables for 7/8" power supply
ZK2000-2xxx-xxxx Cables for M8 I/O connection sockets