Interbus
 
IPxxxx-B400, IL230x-B400 | Fieldbus Box modules for Interbus
Compact Box
IPxxxx-B200
Coupler Box
IL230x-B200
Connector assignment
Module or IP-Link status display
Fieldbus connection input
Fieldbus connection output
Fieldbus status display
3 types of connection
1 | 8 mm snap type connector
2 | M8 screw type connector
3 | M12 screw type connector
(Special functions:
M23 screw type connector)
Power supply feed
Power supply downstream
connection
 IP-Link interface
1 | + 24 V DC Us
2 | + 24 V DC UP
3 | GND
4 | GND
Input
1 | DO1
2 | DO1
3 | DI1
4 | DI1
5 | GND
6 | PE
7 | + 24 V DC
8 | 0 V
9 | n.c
Output
1 | DO2
2 | DO2
3 | DI2
4 | DI2
5 | GND
6 | PE
7 | + 24 V DC
8 | 0 V
9 | RBST
Address selection switch
Configuration interface

IPxxxx-, IL230x-B400 | Fieldbus Box modules for Interbus

All Interbus device manufacturers are obliged to have developed devices certified by the Interbus Club e.V. That means that the devices can be incorporated into any Interbus systems.

 

Configuration

Configuration is started with the Interbus via an identification cycle. The master thereby automatically recognises all connected devices. Identification takes place via an identification code, which is stored in each device, and a long code, which contains the length of the transferred data.

 

Diagnostics

The extensive diagnostic functions of the Beckhoff Interbus devices allow rapid fault localisation. The status of the network connection, the device status, the status of the inputs and outputs and of the power supply are displayed by LEDs.

 

Compact Box

Compact Box modules for Interbus are available for all relevant industrial signals. In addition to digital and analog input and output modules including thermocouple and RTD inputs, there are also incremental encoder interfaces available for displacement and angle measurement in addition to serial interfaces to solve a large number of communication tasks.

 

Coupler Box

The Interbus Coupler Box gathers the I/O data from the Extension Box modules over the interference-free IP-Link fibre optic cable. It detects the connected modules and automatically allocates the input and output data to the process image. Both data consistency and a clear separation of input and output data are ensured. The Coupler Box has four digital inputs and four digital outputs. Other kinds of signal are available in the Extension Box.

System data Interbus | IPxxxx-B400, IL230x-B400
Number of I/O stations depending on the master, max. 256
Number of I/O points depending on the master
Data transfer medium LiYCY 3 x 2 x 0.22 mm²
Cable length max. 400 m between modules
Data transfer rates 500 kBaud
Data transfer time approx. 1 ms in the case of 10 modules for 32 bit input and output each
Technical data IPxxxx-B400 IL230x-B400
Extension modules max. 120 with max. 64 byte input and 64 byte output data
Digital peripheral signals according to I/O type max. 512 inputs and 512 outputs
Analog peripheral signals according to I/O type max. 28 inputs and 28 outputs
Configuration possibility via KS2000
Bus interface 1 x M23 female socket 9-pin, 1 x M23 male socket 9-pin
Power supply control voltage: 24 V DC (20…29 V DC); load voltage: according to I/O type
Power supply connection feed: 1 x M8 male socket, 4-pin; downstream connection: 1 x M8 female socket, 4-pin
Box supply current 85 mA + current consumption of sensors, max. 0.5 A
Auxiliary power current according to I/O type
Electrical isolation control voltage/fieldbus: no, control voltage/inputs or outputs: according to I/O type
Weight approx. 350 g
Operating/storage temperature 0…+55 °C/-25…+85 °C
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos. IP 65/66/67 (conforms to EN 60529)/variable
Approvals CE, UL
Accessories  
KS2000 configuration software for extended parameterisation
Cordsets cordsets and connectors
System  
Interbus For further Interbus products please see the system overview.
 

Compact Box

The Compact Box modules for Interbus offer a wide range of I/O functionalities. All relevant industrial signals are supported. The digital inputs and outputs can be connected either with snap type 8 mm diameter plugs, screw type M8 or M12 connectors. For analog signals the M12 version is used.

IPxxxx-B400 Compact Box for Interbus systems Plug
Digital input
IP1000-B400 Compact Box, 8 digital inputs 24 V DC, 3.0 ms filter 8 mm
IP1001-B400 Compact Box, 8 digital inputs 24 V DC, 3.0 ms filter M8
IP1002-B400 Compact Box, 8 digital inputs 24 V DC, 3.0 ms filter M12
IP1010-B400 Compact Box, 8 digital inputs 24 V DC, 0.2 ms filter 8 mm
IP1011-B400 Compact Box, 8 digital inputs 24 V DC, 0.2 ms filter M8
IP1012-B400 Compact Box, 8 digital inputs 24 V DC, 0.2 ms filter M12
IP1502-B400 Compact Box, 2 up/down counter, 24 V DC, 100 kHz M12
Digital output
IP2000-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 0.5 A 8 mm
IP2001-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 0.5 A M8
IP2002-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 0.5 A M12
IP2020-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) 8 mm
IP2021-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) M8
IP2022-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) M12
IP2040-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 12 A) 8 mm
IP2041-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 12 A) M8
IP2042-B400 Compact Box, 8 digital outputs 24 V DC, IMAX = 2 A (∑ 12 A) M12
IP2512-B400 Compact Box, 2 digital pulse width outputs 24 V DC, IMAX = 2.5 A M12
Digital combi
IP2300-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A 8 mm
IP2301-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A M8
IP2302-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A M12
IP2310-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A 8 mm
IP2311-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A M8
IP2312-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 0.5 A M12
IP2320-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) 8 mm
IP2321-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) M8
IP2322-B400 Compact Box, 4 digital inputs 24 V DC, 3 ms filter, 4 digital outputs 24 V DC, IMAX= 2 A (∑ 4 A) M12
IP2330-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) 8 mm
IP2331-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) M8
IP2332-B400 Compact Box, 4 digital inputs 24 V DC, 0.2 ms filter, 4 digital outputs 24 V DC, IMAX = 2 A (∑ 4 A) M12
IP2400-B400 Compact Box, 16 digital combination inputs/outputs 24 V DC, 3 ms filter, IMAX = 0.5 A 8 mm
IP2401-B400 Compact Box, 16 digital combination inputs/outputs 24 V DC, 3 ms filter, IMAX = 0.5 A M8
Analog input
IP3102-B400 Compact Box, 4 differential analog inputs ±10 V, 16 bit M12
IP3112-B400 Compact Box, 4 differential analog inputs 0/4…20 mA, 16 bit M12
IP3202-B400 Compact Box, 4 analog inputs for resistance thermometer (RTD), PT100…1000, Ni100, 16 bit M12
IP3312-B400 Compact Box, 4 analog inputs for thermocouple, types J, K, L, B, E, N, R, S, T, U, 16 bit M12
Analog output
IP4112-B400 Compact Box, 4 analog outputs 0/4…20 mA, 16 bit M12
IP4132-B400 Compact Box, 4 analog outputs ±10 V, 16 bit M12
Special functions
IP5009-B400 Compact Box, 1 SSI encoder interface M23
IP5109-B400 Compact Box, 1 incremental encoder interface with complementary inputs, 1 MHz M23
IP5209-B400 Compact Box, 1 SinCos encoder interface, 1 VSS M23
IP6002-B400 Compact Box, 1 serial interface RS232C M12
IP6012-B400 Compact Box, 1 serial interface, 0…20 mA (TTY) M12
IP6022-B400 Compact Box, 1 serial interface, RS422, RS485 M12

Coupler Box

The Coupler Box for Interbus has four digital inputs and four digital outputs, optionally with snap type 8 mm diameter connectors, screw type M8 or M12 connectors. Up to 120 Extension Box modules can be connected via the IP-Link communication facility.

IL230x-B400 Coupler Box for Interbus systems Plug
Digital combi
IL2300-B400 Coupler Box, 4 digital inputs 24 V, 3 ms filter, 4 digital outputs 24 V, 0.5 A 8 mm
IL2301-B400 Coupler Box, 4 digital inputs 24 V, 3 ms filter, 4 digital outputs 24 V, 0.5 A M8
IL2302-B400 Coupler Box, 4 digital inputs 24 V, 3 ms filter, 4 digital outputs 24 V, 0.5 A M12

System overview